QSSC -310FA manuali

Manuali dei proprietari e guide per l'utente per Server QSSC -310FA.
We fornisce 3 manuali pdf QSSC -310FA per scaricare gratuitamente in base al tipo di documento: Manuale Utente, Guida Utente, Specifiche


Qssc -310FA Guida Utente (215 pagine)


Marchio: Qssc | Categoria: Server | Dimensione: 8.59 MB |

 

Indice

Copyright

2

Disclaimer

2

Warnings

3

Preface

5

Contents

7

List of Figures

12

List of Tables

16

System Features

20

System Front

21

System Rear

25

Processors

26

System Memory

26

Power Subsystem

26

Power Supply Modules (PSU)

29

Cooling Subsystem

31

Fan Modules

33

Hot Swap PCI Express Slots

34

Peripherals

34

Hot-Swap Hard Drive

35

Optical Drive Bay

36

System Boards

37

Main Board

38

Memory Riser

41

I/O Riser

43

SAS Riser

44

Front Panel Fan Board

45

Operator Panel

46

Hot Swap Backplane Board

49

Power Distribution Board

51

Powering Up the Server

53

Shutting Down the Server

53

Chapter 3: Server Utilities

54

Secure Shell (SSH)

55

BMC Users

55

Session Support

55

Access BMC via RMM3

56

SYSCFG Utility

57

SYSCFG INI file

58

SEL Viewer

59

System Management Software

60

Using DPCCLI

61

DPCCLI ‘vs Telnet

61

Intel SNMP subagent

62

SNMP Master Agent

62

Scenarios and best practices

63

BMC SOL Configuration

64

BIOS Configuration

64

Remote Management

65

Using Serial Over LAN

67

Before You Begin

68

Hot-Swapping a Hard Drive

71

Hot Swapping a Power Supply

74

Removing System Fan Modules

80

Hot Swapping Memory Risers

82

Installing a Memory Riser

84

Hot Adding a Memory Riser

85

Removing a Memory Air Baffle

86

Installing DIMMs

89

Removing DIMMs

91

Installing the Rack Rail

94

Removing the Rack Rails

95

Removing the Top Cover

100

Installing the Top Cover

101

Version 1.0

102

Removing the SAS Riser

104

Installing the SAS Riser

105

Installing the I/O Riser

110

Removing the I/O Riser

110

Installing the RMM 3

111

Removing the Intel®RMM3

112

Removing the Memory Dividers

113

Servicing the Processors

118

Installing a Processor

119

Removing a Processor

123

Removing the Memory Rug

123

Installing the Memory Rug

124

Replacing the Main Board

125

Installing the Main Board

126

Removing the Fan Cage

128

Installing the Fan Cage

129

Replacing the Operator Panel

131

Replacing the CMOS Battery

139

Using the BIOS and utilities

141

Page Layout

142

BIOS Setup Utility Screens

143

Main Screen

144

Advanced Screen

146

Memory Configuration Screen

150

USB Configuration Screen

156

PCI Configuration Screen

157

Boldface)

158

Help Text Comments

158

Security Screen

159

Server Management Screen

161

Console Redirection Screen

162

BMC LAN Configuration

163

Boot Options Screen

166

Add New Boot Option Screen

168

Delete Boot Option Screen

168

Hard Disk Order Screen

169

CDROM Order Screen

169

Floppy Order Screen

170

Network Device Order Screen

170

BEV Device Order Screen

171

Boot Manager Screen

171

Error Manager Screen

172

Exit Screen

172

Loading BIOS Defaults

173

Clearing the BIOS Password

173

Appendix A: POST Codes

175

POST Error Beep Codes

179

BMC Beep Codes

179

English

180

Deutsch

182

Français

184

Español

186

Italiano

188

Intended Application Uses

192

Site Selection

192

Equipment Handling Practices

192

System Access Warnings

193

Rack Mount Warnings

193

Other Hazards

194

Zielbenutzer der Anwendung

196

Standortauswahl

196

Handhabung von Geräten

196

Warnhinweise für Racks

197

Sélection d’un emplacement

199

Selección de la ubicación

203

Manipulación del equipo

204

Sustitución de la batería

206

Product Safety Compliance

207

Industry Canada (ICES-003)

210

VCCI (Japan)

210

BSMI (Taiwan)

210

Appendix E: Getting Help

212

Glossary

213

Reference Documents

215

Qssc -310FA Specifiche (322 pagine)


Marchio: Qssc | Categoria: Server | Dimensione: 6.61 MB |

 

Indice

Contents

3

List of Figures

13

List of Tables

16

1. Introduction

21

2. Main Board

23

2.2 Functional Architecture

27

2.2.2 Intel® 7500 Chipset

30

2.2.2.2 Intel® QPI Features

31

2.2.2.5 Controller Link (CL)

32

2.3.1 ICH10R Southbridge

33

2.3.2 PCI-Express Subsystem

36

2.3.6 Clock Subsystem

37

2.3.6.1.1 CK MNG

39

2.3.8 BIOS Flash Devices

40

2.3.9 USB 2.0 Subsystem

40

2.3.10 Post Code LEDs

41

3.1 Introduction

47

3.1.2 Non IPMI Features

48

3.2 Functional Architecture

49

3.2.2 SMBus Block Diagram

50

3.3 Supported Features

52

3.3.4 Memory Throttling

53

3.3.5 Chassis Intrusion

53

4. Memory Riser

54

® SMI Status Frame

55

4.2.2 DDR3 Functionality

56

4.3 Functional Architecture

57

4.3.3 Memory Riser LEDs

58

4.3.4 Power Rails

58

5. I/O Riser

59

5.2 Functional Architecture

60

5.3 Video Subsystem

60

5.4 USB Subsystem

61

7. SAS Riser

65

7.2.1 I²C Interface

66

7.2.2 Host Interface

66

7.2.3 Internal SAS Interface

66

7.2.4 Memory Interface

67

7.2.5 Debug Jumpers

67

7.2.7 SAS Riser Power

67

8. Hot Swap Backplane (HSBP)

68

8.2 Functional Architecture

71

8.2.1 SAS Buses

72

8.2.2 Hot-swap Backplane

72

8.2.4 SAS Controller

72

8.2.5.1 SPI Flash

73

8.2.7.2 SAS Status LEDs

73

2C* Interface

74

2C* Bus

74

2C* Bus IPMB

74

8.2.10 Resets

75

8.2.11 Clock Generation

75

8.2.12 Programmed Devices

75

9. System Overview

76

9.1.1 Fan Subsystem

78

9.1.2 Operator Panel

79

9.3 Power Subsystem

80

9.4 Cooling Subsystem

83

9.5 Specifications

83

9.6 Component Enumeration

84

9.6.2 Fans

85

9.6.3 Hard Drive Slots

86

9.6.4 PCIe Slots

86

9.6.5 Memory Riser Boards

86

9.6.7 NIC Ports

87

9.6.8 USB Ports

87

9.6.9 Power Supply Units

88

10.1.1 Base Chassis

89

10.1.2 Top Cover

89

10.1.3 Slide Rails

89

10.1.4 Cable Management Arm

90

10.2.1 Power Supply Modules

91

10.2.2 Fan Subsystem

92

10.3 Main Board Subsystem

94

10.4.1 Hard Drive Carrier

96

10.4.2 Optical Drive

97

10.4.3 5 ¼” Tape Drive Bay

98

11. Cables and Connectors

99

11.3.1 Serial Port

101

11.3.2 Video Ports

102

12. 850W Power Supply

104

12.3 AC Input Requirement

105

12.4 DC Output Requirements

106

12.4.10.1 Power Supply Fail

108

12.4.10.2 Power Good

108

12.4.10.3 AC OK

108

13.1 Introduction

109

13.2.2 Voltage Regulation

114

13.2.10 PMBus Requirements

116

14.1 Architectural Overview

119

14.3 Front Panel Control

123

15.1 BIOS Architecture

126

16. BIOS Initialization

127

Technology

130

Virtualization Technology

131

16.1.24 Cbox Error Records

132

16.2 Memory

133

16.2.2 POST Error Codes

134

16.2.3.2 High-Memory Reclaim

135

16.2.3.3 ECC Support

135

16.2.5 Memory Test

136

16.2.6 Memory Scrub Engine

136

16.2.10.1 Lock Step Mode

143

16.2.10.2 Interleaving Mode

143

16.2.10.3 Sparing Mode

144

16.2.10.4 Mirroring Mode

144

Copy of Memory Data

146

16.2.11 Memory Hot-Plug

148

16.2.11.1 Detailed Flow

149

Specification

158

16.3.1 Scan Order

168

16.4 PnP ISA

169

16.5 Keyboard / Mouse

169

16.7 Removable Media Drives

170

16.8 PCI Express Hot Plug

170

HW Domain

171

User Domain OS Domain

171

Native Hot-plug

171

OS Domain

171

ACPI-assisted Hot-plug

171

16.9.1.2 Fan Profile Option

172

C reads this using PECI)

175

17. BIOS User Interface

176

17.2.2.2 Keyboard Commands

177

17.2.2.3 Menu Selection Bar

178

17.2.3.1 Main Screen

179

17.2.3.2 Advanced Screen

181

17.2.3.4 Security Screen

193

17.2.3.8 Boot Options Screen

199

17.2.3.11 Exit Screen

206

17.3 Loading BIOS Defaults

207

18. BIOS Update Support

208

19.1 Boot Device Selection

209

19.1.3 Boot Order Table

210

Name Length Description

212

19.1.3.4 BOT Device Name(s)

213

Power Interface Specification

215

19.2.3.1 WHEA Overview

216

19.2.4 EFI Optimized Boot

217

19.4 Sleep and Wake Support

218

20.1 IPMI

220

20.2 Console Redirection

220

20.3 IPMI Serial Interface

221

Use Case Model

222

20.5.1 Access Methods

223

Length Value Description

224

Definition

225

Length Value Description

226

20.6 Security

231

20.6.3.2 Physical Presence

232

21. BIOS Error Handling

233

21.1.4 Boot Event

234

21.2.2 NMI on Fatal Errors

235

ED1 ED2 ED3

236

21.2.3.2 Legacy PCI Sensors

238

21.2.3.3 Memory Sensors

238

21.2.3.6.2 OS Boot timeout

240

21.2.3.7 Boot Event

241

21.3.1 Diagnostic LEDs

242

21.3.2 POST Code Checkpoints

242

21.3.4 POST Error Beep Codes

246

22.1 Feature Support

248

C interfaces

250

23.1 Power System

251

23.1.3 Power up Sequence

252

23.1.4 Power Down Sequence

252

23.1.5 Power Control Sources

252

23.1.6 Power State Retention

253

23.1.8 Wake-On-LAN (WOL)

253

23.3 System Reset Control

254

23.4 BMC Reset Control

255

23.5 System Initialization

255

24.1.1 BSP Identification

257

24.1.2 Boot Control Support

257

24.1.3 Post Code Display

257

24.2.1 Power LED

257

24.2.2 System Status LED

257

24.2.3 Chassis ID LED

259

24.3 Private Management I

260

C Buses

260

24.4 Watchdog Timer

260

24.6 System Event Log (SEL)

261

24.7.2 Initialization Agent

262

24.8.2 BMC FRU ID Mapping

262

24.9.1 Signal Generation

263

24.10 Sensor Rearm Behavior

264

24.11 Processor Sensors

264

24.11.1.1 Processor Presence

265

24.12 Voltage Monitoring

266

24.13.1 Hot Swap Fans

267

24.13.3 Fan Domains

268

24.13.4 Nominal Fan Speed

268

24.13.4.1.2 Domain Maximum

269

24.13.4.2 Clamp

270

24.13.4.3 Sensor Failure

271

24.13.5.1 Fan Profiles

271

24.13.5.2 ASHRAE Compliance

272

24.18 Power Throttle Sensor

273

24.20.1 Semaphore Operation

274

24.21 HeartBeat LED

276

24.22 CSS LED

277

24.23 Global Fan Fault LED

277

24.25 Power Unit Management

278

24.25.1.1 Power Off

279

24.25.1.2 AC Lost

279

24.25.1.4 Power Unit Failure

279

IPMI Sensor Characteristics

280

Event Logging

281

24.29 BMC Self Test

282

24.30 BMC Test Commands

282

24.32 Hot-Swap Controller

284

24.34 CATERR Reporting

284

25.3 Sessions

287

25.4 Media Bridging

288

25.6.2 Receive Message Queue

289

25.6.5 SMM Interface

290

25.7.1 BMC as I

290

C Master Controller on IPMB

290

25.7.2 IPMB LUN Routing

291

25.8.1 COM Port Switching

292

25.8.2 Terminal Mode

292

25.9 LAN Interface

293

25.9.3 RMCP / ASF Messaging

294

25.9.6 DHCP BMC Hostname

295

26. BMC Flash Update

299

26.3 Boot Recovery Mode

300

27. BIOS-BMC Interactions

302

28. BMC-HSC Interactions

303

29. Sensors

304

Table 202. IBMC Core Sensors

306

Contrib. To

307

30.1.1 I2C Interfaces

313

30.1.3 GPIO Pins

313

31.1 Platform Determination

314

31.2 System Initialization

314

31.3 System Event Log (SEL)

315

31.6 Temperature Monitoring

315

31.7 Disk Management

316

32.1 LUNs

317

32.2 Sensors

317

33. HSC Firmware Update

319

Glossary

320

Reference Documents

322


QSSC dispositivi